| rozstaw lamel: 3.5-7mm z grzałkami elektrycznymi | |||||||||
| TYP | MOC CHŁODNICZA | POWIERZCHNIA | POJEMNOŚĆ WĘŻOWNICY | WYDATEK POWIETRZA | WYRZUT POWIETRZA | MOC GRZAŁEK ODSZRANIANIA | PRZYŁĄCZA | ||
| R404a | WYMIANY | [dm3] | [m3/h] | [m] | [W] | ||||
| [W] | [m2] | ||||||||
| T.room= +2oC | |||||||||
| ΔT=10K | CIECZ | GAZ | ODŁYW | ||||||
| TEB329M | 1910 | 7,16 | 1,73 | 595 | 2,5 | 850 | 1/2’’ | 5/8’’ | 1/2’’ |
| WENTYLATORY | |||||||||
| TYP | ILOŚĆ x ŚREDNICA [mm] | POBÓR PRĄDU [A] | MOC [W] | NAPIĘCIE ELEKTRYCZNE [V/Hz] | |||||
| TEB329M | 3x200 | 0,75 | 129 | 230v/50Hz | |||||
| WYMIARY [mm] | |||||||||
| TYP | P2 | P3 | A | B | |||||
| TEB329M | 971 | - | 1106 | 438 | |||||
| T.room | -5℃ | 0℃ | 2℃ | 4℃ | 6℃ | 8℃ | 10℃ | 12℃ | |
| △T 10 (watt) | 1750 | 1880 | 1910 | 1940 | 1960 | 1990 | 2030 | 2090 | |
| △T 9 (watt) | 1570 | 1690 | 1710 | 1740 | 1760 | 1780 | 1840 | 1880 | |
| TEB329M | △T 8 (watt) | 1390 | 1490 | 1510 | 1520 | 1540 | 1570 | 1620 | 1660 |
| △T 7 (watt) | 1200 | 1280 | 1300 | 1310 | 1330 | 1360 | 1390 | 1430 | |
| △T 6 (watt) | 989 | 1060 | 1070 | 1080 | 1090 | 1130 | 1160 | 1200 | |
| △T 5 (watt) | 780 | 842 | 854 | 867 | 880 | 906 | 932 | 959 |